Closed cell gives you more R-value per inch and slows moisture, and at 1.5 inches it works as a vapor barrier, but it costs more. Open cell is lighter, soaks up more sound and costs less per inch, but it gives less R-value per inch. Which one wins depends on the space. We spray both in Reno, and when you ask for a free estimate we write the foam type into the scope.
Closed cell is the dense, hard kind of spray foam, what the trade calls 2-lb foam. It gives you more R-value per inch than open cell, and it does three jobs in one layer: it insulates, stops air leaks and slows moisture.
One inch of JM Corbond closed-cell foam is an air barrier and 1.5 inches a vapor barrier, by its maker's figures. In a shallow rafter bay or a rim joist, that is a lot of work from very little depth.

Open cell is the soft, light, spongy kind, about a quarter of the density of closed cell. It costs less per inch and gives less R-value per inch. It also soaks up sound, so it's a good pick for a wall or ceiling where you want less noise between rooms. The sound insulation page covers that.
Open cell lets water vapor pass, so it is not a moisture barrier. That is why it belongs in dry, protected places and in roof assemblies designed for it.
Closed cell. JM Corbond closed-cell foam is rated R-7.0 per inch by its maker, Johns Manville. Open cell gives less per inch.
That gap matters most where the framing is shallow, like a roofline or rim joist. Closed cell gets more R-value into the depth you have. Open cell needs more inches, and the space may not have them.
Closed cell is the better foam in a lot of places, but it has real drawbacks:
Careless installs cause most spray foam problems. The spray foam safety page has the details.
Reno is in climate zone 5B, which calls for a lot of R-value, so depth matters when you choose the foam. The R-value guide shows how much total insulation a house needs. Here is how we usually choose by space.
For an unvented roofline, we usually spray closed cell on the underside of the roof deck. It seals air leaks and gets the R-value into the depth of the rafters. Open cell can work there when the job is designed correctly, with the right thickness, roof assembly and coating where code requires. We put the choice in the scope. The roof and cathedral ceiling page has more.
If you only need to top up an attic floor, blown-in insulation is usually the cheaper way.
We lean toward closed cell here. Rim joists and crawl space walls are where cold air and damp collect, and closed cell doesn't soak up water the way open cell does. See crawl space insulation for cold floors.
Closed cell on the underside of the roof panels and walls is our pick. Open cell is soft and lets vapor through, so it is a poor match against bare steel. The commercial insulation page explains why metal buildings drip.
Not sure which space needs what? Tell us about the building when you ask for a free estimate. We'll write the foam type, thickness and target R-value into the scope. The spray foam insulation page covers how a job goes.
Yes. It's common to put closed cell where moisture or shallow depth is the problem, like a rim joist or roof deck. Open cell goes where there's room to fill and you want lower cost or less noise. The scope says which foam goes where.
It is when the space is shallow, damp or made of steel, because you get more R-value per inch and a layer that slows moisture. Where there is plenty of depth and the space stays dry and protected, open cell can be the better buy.
No, it's dense and doesn't absorb water the way open cell does. It won't fix a leak, though. If water is getting in, that gets repaired before any foam goes on.
It comes down to how deep the framing is, whether the space sees moisture, and what is behind the foam. We check those things at the estimate and tell you why we chose one foam over the other.
Ask for a free estimate and we'll write the foam type, thickness and R-value into the scope for your attic, crawl space or shop.
Licensed & insured · Free estimates